DaikinIndustries Ltd. Daikin Industries Ltd. offers kitchen ventilation systems such as Heat Reclaim Ventilator with DX-Coil and Heat Reclaim Ventilator. Dover Corp.
UnityAir-con Systems - Offering Daikin Heat Reclaim Ventilation System, Ventilation Systems, Air Ventilation, एयर वेंटिलेशन सिस्टम, वायु-संचालन प्रणाली in Delhi, Delhi. Get best price and read about company. Get contact details and address| ID: 11360450997
Daikinfresh air portfolio. All of our ventilation units offer heat recovery as a standard feature and can recover up to 81% of outgoing heat. We offer a wide range of solutions to cover almost any application, starting from as low as 10 m3/h up to 140,000 m3/h.
CleanAir stock a large range of air ventilation and diffusion hardware, used to and create individual systems bespoke to client requirements. As a starting point the forms of ventilation to consider are: Ventilation and Heat Reclaim units for air conditioned climate control. Evaporative Air Conditioning for fresh air ventilation and cooling.
ofthe Heat Reclaim Ventilator. 6.Message The following messages are displayed. "This function not available." 'LVSOD\HG IRU D IHZ VHFRQGV ZKHQ DQ operation button is pressed and the indoor unit does not have the corresponding function. ,I D QXPEHU RI LQGRRU XQLWV DUH LQ RSHUDWLRQ WKH PHVVDJH ZLOO DSSHDU RQO\ LI QRQH RI WKH
TotalHeat Exchanger HRV (Heat Reclaim Ventilation) Operation manual HRV - Heat Reclaim Ventilation Before using the DAIKIN HRV, be sure to read this operation manual thoroughly. If you have any problems or there is a malfunction, please refer to this operation manual. Please keep this manual for your future reference
. Daikin Advantage Improved Air Quality A steady inflow of fresh, conditioned air improves air quality of indoor settings. Energy Efficiency Energy recovery between supply air and exhaust air eliminates waste to realize efficient ventilation. Flexible Installation Daikin’s unique modular system enables each unit to be tailor-fitted to the exact dimensions required. Product Lineup Refreshes stale indoor air with fresh outdoor air. Processes outdoor air to bring it near temperature of indoor air and distributes the air throughout the room. Indoor humidity is appropriately controlled by humidification and/or dehumidification. Outdoor-Air Processing Unit Supplying outdoor air at the same temperature of the room maintains comfort and lessens heat load caused by ventilation. * Can be connected only to VRV Heat Reclaim Ventilator Daikin’s unique heat exchange element realizes efficient heat exchange between supply air and exhaust air. High external static pressure enables flexible installation. Heat Reclaim Ventilator with DX-Coil A temperature adjustment function has been added to the Heat Reclaim Ventilator to better maintain comfort and lessen heat load caused by ventilation. * Can be connected only to VRV DESICA*:Heat Pump Desiccant Humidity Control Outdoor-Air Unit The DESICA permits individual control of humidity and temperature, by the hybrid DESICA element which contains a water absorption material and a heat exchanger, with lower energy consumption compared to conventional humidity control devices according to Daikin tests. * DESICA is a Daikin registered trademark in Japan. Technology Heat Exchange Element The thin film material allows only small water molecules moisture to penetrate while blocking out larger molecules such as CO2 . This eliminates waste by preventing the heat and moisture of the conditioned air from escaping outdoors and promotes efficient ventilation using less energy. Learn More Daikin's Unique Heat Pump Desiccant The heat pump desiccant integrates the heat exchanger and desiccant element to enable highly-efficient dehumidification and humidification with no need to supply or drain water. Learn More Wired Remote Controller Stylish Remote Controller Sleek stylish design DAIKIN APP for Installer simplifies the advanced settings such as field settings Useful administration / Shorter and Easier installation Stylish Remote Controller Navigation Remote Controller Operation is easy and smooth, just follow the indication on the remote controller Weekly schedule can be set 5 actions per day for each day of the week Circulation airflow, a function for the latest cassette type can be set Simplified Remote Controller Simple operation by using only six buttons, and users have direct access to basic functions Intuitive design by using pictograms enables user-friendly interface Overseas guests at hotels understand functions without having to know a foreign languages Case Study Case Study Visit the Daikin Global Case Studies page for detailed examples of installations Learn More After Sales Service A global support system delivers timely solutions to all needs. Learn More Preventive Maintenance Service AVAILABILITY The products or features on this page may not be available in your region. Please visit your local website for details on the products and features available in your region.
VAM-HVE VAM-HVE Heat Reclaim Ventilator Daikin also offers heat reclaim ventilator systems; our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range -15 to 50°C. These units provide high enthalpy efficiency due to the greatly enhanced performance of the thin film element. Furthermore, ESP* of up to 235Pa offers greater design flexibility to your air conditioning solution. Other features include Night Purge Operation night time free-cooling, interlocked operation with VRV Cassette presence sensor and optional CO2, indoor & outdoor humidity sensors for optimal operation. By incorporating heat reclaim ventilators into your air conditioning design, heat loads can be reduced and your plan size can be better optimised. *Max ESP varies from 130 Pa to 235 Pa depending on the model class Download Brochure All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions. Technical Specifications Available Options System Reverse Cycle Capacities Indoor Type Heat Reclaim Ventilator Power Supply Refrigerant VAM-HVE Flyer Our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range. Furthermore, improved external static pressures offer greater design flexibility to support variety of duct layouts. Send the brochure to me. Enter your email below to receive the brochure link in your inbox
Product categoryVRV Air Conditioner›Heat Reclaim VentilationModel HRV VAM250GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVESpecificationMODELVAM250GJVEVAM500GJVEVAM650GJVEVAM800GJVEVAM1000GJVEVAM1500GJVEVAM2000GJVEPower Supply1-phase, 220-240 V/ 220 V, 50 HzTemp. ExchangeEf ciency50/60 HzUltra-High%75/7574/7475/7572/7278/7872/7277/77High75/7574/7475/7572/7278/7872/7277/77Low79/7980/ ciency50/60 HzFor HeatingUltra-High%71/7267/ CoolingUltra-High%63/6355/5561/6161/6164/6461/6162/62High63/6355/5561/6161/6164/6461/6162/62Low66/6659/ HzHeatExchangeModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Bypass ModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Sound Level 50/60 HzHeat ExchangeModeUltra-HighdBA27-29/ ModeUltra-HighdBA steel plateInsulation MaterialSelf-extinguishable polyurethane foamDimensions HXWXDmm278X810X551306X879X800338X973X832387X1,111X832387X1,111X1,214785X1,619X832785X1,619X1,214Machine Weighkg2432455567129157Heat Exchange SystemAir to air cross ow total heat Sensible heat+latent heat exchangeHeat Exchange Element MaterialSpecially processed non-ammable paperAir FilterMultidirectional brous eecesFanTypeSirocco fanAir ow Rate50/60 HzUltra-Highm3/h250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000High250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000Low155/155320/295500/470700/670860/8401,320/1,2601,720/1,580External Static Pressure50/60 HzUltra-HighPa70/96105/15085/125133/170168/192112/150116/ Duct Diametermmø150ø 200ø 250ø 350Unit ambient condition-15°C–50°CDB, 80%RH or lessAS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.
Available in Capacities Refrigerant Daikin also offers heat reclaim ventilator systems; our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range -15 to 50°C. These units provide high enthalpy efficiency due to the greatly enhanced performance of the thin film element. Furthermore, ESP of up to 235Pa offers greater design flexibility to your air conditioning solution. Other features include Night Purge Operation night time free-cooling, interlocked operation with VRV Cassette presence sensor and optional CO2, indoor & outdoor humidity sensors for optimal operation. By incorporating heat reclaim ventilators into your air conditioning design, heat loads can be reduced and your plan size can be better optimised. Download Brochure Engineering Data All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions. Contact a Daikin Sales Engineer A Daikin Sales Engineer will assess, plan and install the right air conditioning solution for you, with creativity and sensitivity to the needs of your family or business. AAF offers a comprehensive air filtration portfolio to provide clean air solutions for commercial and industrial applications.
Residential Light Commercial Commercial Home > Commercial > Ventilation Units > Energy Recovery Ventilator VAM_GVJU Overview Features Resources This product is designed to maintain good indoor air quality by providing sufficient levels of fresh outside air and recover waste heat from extracted air leaving the conditioned zone. This new ERV unit is fully compatible with Daikin’s DIII-NET communications. Provides energy-saving heat recovery ventilation via a new heat exchanger with high temperature and enthalpy recovery efficiency Design flexibility thanks to high static pressure fans and the capability for use in a wide range of climates 5°F to 122°F DB and 80% RH or less* Wide range of functions such as independent operation, interlock with other HVAC systems and automatic night purge to reduce cooling loads and increase energy savings Interlocked simultaneous operation with VRV indoor units through a single controller Auto mode switches the ventilation mode total heat exchange mode to bypass mode according to the operating status of air conditioner system Pre-cooling/heating control function to delay the start of ventilation during air conditioner start-up for higher energy savings Supply and exhaust fresh-up operation modes to control pressure within a space Filter sign and display reset notifies when filter changes are required ESP as high as Sound levels as low as dBA for sound sensitive installation locations * Note Certified in accordance with the AHRI ERV Certification Program, which is based on AHRI Standard 1060. Certified units may be found in the AHRI Directory at Performance characteristics certified to AHRI Standard 1060 based on the following conditions - The cooling effectiveness shall be based on 95°F DB / 78°F WB for the entering supply air and 75°F DB / 63°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow. - The heating effectiveness shall be based on 35°F DB / 33°F WB for the entering supply air and 70°F DB / 58°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow.
daikin heat reclaim ventilator